x-EM OPTES
Help

Using the Optimization tab

  1. In Filters, choose a Grid (site).
  2. Select one or more optimization types and one or more runtimes.
  3. Set the datetime range, or use the shortcuts Full horizon, First 24 h, Today.
  4. Select the variables to plot and press Apply.
  5. In Trends: zoom with the mouse wheel or with Shift + drag, go back with Reset zoom; click an item of the legend to show or hide its series; CSV downloads the plotted data.
  6. Statistics summarizes each plotted series; the Grid panel shows the properties and devices of the site.

Using the Forecast tab

  1. Choose the Grid (when more than one is available).
  2. Set the range with From and To, or with the Day, Week, Month buttons.
  3. Choose the error measure, nMAE or nRMSE: it applies to the error cards and to the error by hour.
  4. In the curves chart, drag to zoom on a time window and use Reset zoom to go back; click an item of the legend to show or hide its series.
  5. Below, the error by hour of the day and the forecast vs. reference scatter plots.

Glossary

Times are shown in the time zone of your browser. Terms with a dotted underline in the dashboard show the same description on hover.

Optimization

Variables: Generation and load

PV generation generation [kW]
Power produced by the photovoltaic system of the site.
Total load load [kW]
Total power consumed by the site: fixed load plus flexible load.
Fixed load fix_load [kW]
Part of the consumption that cannot be shifted in time.
Flexible load flex_load [kW]
Part of the consumption that can be shifted in time (for example thermal or deferrable loads).
Optimized flexible load flex_load_opt [kW]
Flexible load as rescheduled by the optimization.
Optimized total load load_opt [kW]
Total load after the optimization: fixed load plus optimized flexible load.

Variables: Grid exchange

Grid exchange (PCC) pcc [kW]
Net power at the point of connection with the grid: positive = export, negative = import (grid export minus grid import).
Grid import w_abs_grid [kW]
Power withdrawn from the grid.
Grid export w_inj_grid [kW]
Power fed into the grid.

Variables: Battery storage

Battery charging w_ch [kW]
Power used to charge the battery energy storage system (BESS).
Battery discharging w_dis [kW]
Power delivered by the battery energy storage system (BESS).
Battery state of charge soc [0–1]
Energy stored in the battery as a fraction of its capacity (0 = empty, 1 = full).

Variables: Prices

Energy purchase price energy_price [€/kWh]
Price of the energy withdrawn from the grid in each interval, as used by the optimization.
Energy selling price energy_price_inj [€/kWh]
Price received for the energy fed into the grid, as used by the optimization.
Time-band price price [€/kWh]
Energy price of the tariff time band the interval belongs to.

Optimization types

Battery optimization (forecast) bess_fc
Schedule of the battery storage computed from forecast generation, load and prices.
Battery optimization (measured) bess_meas
Battery optimization recomputed on measured generation and load, to compare with the forecast-based schedule.
Flexible load optimization (forecast) flex_load_fc
Schedule of the flexible loads computed from forecast generation, load and prices.
Flexible load optimization (measured) flex_load_meas
Flexible load optimization recomputed on measured generation and load, to compare with the forecast-based schedule.

Grid properties

Grid code
Technical identifier of the grid (site).
Grid name
Readable name of the grid (site).
District
District where the site is located.
City
City where the site is located.
Activity
Kind of site, for example industrial, prosumer or PV production.
Energy cost [€/kWh]
Reference cost of the energy bought from the grid.
Diesel consumption
Diesel consumption of on-site generators, if any.
Time zone
Local time zone of the site.
Time-band prices [€/kWh]
Energy prices of the tariff time bands, when the site has a time-band contract.
Market zone
Electricity market bidding zone of the site.
Substation power [kW]
Maximum power that can be exchanged with the grid at the site's substation.
Enabled
Whether the site is active in the optimization.

Devices

Electric loads
Electrical consumers of the site.
Thermal loads
Heating or cooling consumers of the site.
Photovoltaic
Photovoltaic generators; the power is the nominal (peak) power.
Battery storage (BESS)
Battery energy storage systems; power is the nominal power, capacity the storable energy (kWh).

Forecast

Quantities

Global horizontal irradiance (GHI) [W/m²]
Solar power received per square metre by a horizontal surface; it drives photovoltaic production.

Series

Enhanced model · 15 min
Forecast model developed to improve the accuracy of the weather forecasts for the site.
Meteo 1 · 1 h
Forecast from a weather service; each hourly value is the mean of the hour.
Meteo 2 · 1 h
Forecast from a second weather service; each hourly value is the mean of the hour.
Base model (reference) · 15 min
Reference series against which the forecasts are evaluated.

Errors and charts

nMAE [%]
Normalized mean absolute error: mean of |forecast − reference| divided by 1000 W/m² (standard test conditions). Lower is better.
nRMSE [%]
Normalized root mean square error: square root of the mean squared error divided by 1000 W/m². It weights large errors more than the nMAE. Lower is better.
N
Number of quarter-hours in which forecast and reference are compared.
Resolution
Time step of a series. Each value is the mean over the interval ending at its time stamp; an hourly value is compared with each quarter-hour of its hour.
Error by hour of the day [%]
nMAE or nRMSE computed separately for each hour of the day, in the browser time zone.
Forecast vs. reference [W/m²]