Using the Optimization tab
- In Filters, choose a Grid (site).
- Select one or more optimization types and one or more runtimes.
- Set the datetime range, or use the shortcuts Full horizon, First 24 h, Today.
- Select the variables to plot and press Apply.
- In Trends: zoom with the mouse wheel or with Shift + drag, go back with Reset zoom; click an item of the legend to show or hide its series; CSV downloads the plotted data.
- Statistics summarizes each plotted series; the Grid panel shows the properties and devices of the site.
Using the Forecast tab
- Choose the Grid (when more than one is available).
- Set the range with From and To, or with the Day, Week, Month buttons.
- Choose the error measure, nMAE or nRMSE: it applies to the error cards and to the error by hour.
- In the curves chart, drag to zoom on a time window and use Reset zoom to go back; click an item of the legend to show or hide its series.
- Below, the error by hour of the day and the forecast vs. reference scatter plots.
Glossary
Times are shown in the time zone of your browser. Terms with a dotted underline in the dashboard show the same description on hover.
Optimization
Variables: Generation and load
- PV generation generation [kW]
- Power produced by the photovoltaic system of the site.
- Total load load [kW]
- Total power consumed by the site: fixed load plus flexible load.
- Fixed load fix_load [kW]
- Part of the consumption that cannot be shifted in time.
- Flexible load flex_load [kW]
- Part of the consumption that can be shifted in time (for example thermal or deferrable loads).
- Optimized flexible load flex_load_opt [kW]
- Flexible load as rescheduled by the optimization.
- Optimized total load load_opt [kW]
- Total load after the optimization: fixed load plus optimized flexible load.
Variables: Grid exchange
- Grid exchange (PCC) pcc [kW]
- Net power at the point of connection with the grid: positive = export, negative = import (grid export minus grid import).
- Grid import w_abs_grid [kW]
- Power withdrawn from the grid.
- Grid export w_inj_grid [kW]
- Power fed into the grid.
Variables: Battery storage
- Battery charging w_ch [kW]
- Power used to charge the battery energy storage system (BESS).
- Battery discharging w_dis [kW]
- Power delivered by the battery energy storage system (BESS).
- Battery state of charge soc [0–1]
- Energy stored in the battery as a fraction of its capacity (0 = empty, 1 = full).
Variables: Prices
- Energy purchase price energy_price [€/kWh]
- Price of the energy withdrawn from the grid in each interval, as used by the optimization.
- Energy selling price energy_price_inj [€/kWh]
- Price received for the energy fed into the grid, as used by the optimization.
- Time-band price price [€/kWh]
- Energy price of the tariff time band the interval belongs to.
Optimization types
- Battery optimization (forecast) bess_fc
- Schedule of the battery storage computed from forecast generation, load and prices.
- Battery optimization (measured) bess_meas
- Battery optimization recomputed on measured generation and load, to compare with the forecast-based schedule.
- Flexible load optimization (forecast) flex_load_fc
- Schedule of the flexible loads computed from forecast generation, load and prices.
- Flexible load optimization (measured) flex_load_meas
- Flexible load optimization recomputed on measured generation and load, to compare with the forecast-based schedule.
Grid properties
- Grid code
- Technical identifier of the grid (site).
- Grid name
- Readable name of the grid (site).
- District
- District where the site is located.
- City
- City where the site is located.
- Activity
- Kind of site, for example industrial, prosumer or PV production.
- Energy cost [€/kWh]
- Reference cost of the energy bought from the grid.
- Diesel consumption
- Diesel consumption of on-site generators, if any.
- Time zone
- Local time zone of the site.
- Time-band prices [€/kWh]
- Energy prices of the tariff time bands, when the site has a time-band contract.
- Market zone
- Electricity market bidding zone of the site.
- Substation power [kW]
- Maximum power that can be exchanged with the grid at the site's substation.
- Enabled
- Whether the site is active in the optimization.
Devices
- Electric loads
- Electrical consumers of the site.
- Thermal loads
- Heating or cooling consumers of the site.
- Photovoltaic
- Photovoltaic generators; the power is the nominal (peak) power.
- Battery storage (BESS)
- Battery energy storage systems; power is the nominal power, capacity the storable energy (kWh).
Forecast
Quantities
- Global horizontal irradiance (GHI) [W/m²]
- Solar power received per square metre by a horizontal surface; it drives photovoltaic production.
Series
- Enhanced model · 15 min
- Forecast model developed to improve the accuracy of the weather forecasts for the site.
- Meteo 1 · 1 h
- Forecast from a weather service; each hourly value is the mean of the hour.
- Meteo 2 · 1 h
- Forecast from a second weather service; each hourly value is the mean of the hour.
- Base model (reference) · 15 min
- Reference series against which the forecasts are evaluated.
Errors and charts
- nMAE [%]
- Normalized mean absolute error: mean of |forecast − reference| divided by 1000 W/m² (standard test conditions). Lower is better.
- nRMSE [%]
- Normalized root mean square error: square root of the mean squared error divided by 1000 W/m². It weights large errors more than the nMAE. Lower is better.
- N
- Number of quarter-hours in which forecast and reference are compared.
- Resolution
- Time step of a series. Each value is the mean over the interval ending at its time stamp; an hourly value is compared with each quarter-hour of its hour.
- Error by hour of the day [%]
- nMAE or nRMSE computed separately for each hour of the day, in the browser time zone.
- Forecast vs. reference [W/m²]
- Each point is one quarter-hour: forecast on one axis, reference on the other. Points on the diagonal are perfect forecasts.